 CentrolHole Series  
TYPE
COUPLES
Imax
Umax
Qcmax(w)
ΔTmax(℃)
DIMENSIONS
R
(A)
(V)
ΔT =0
Qc=0
(mm)
(Ω)
Th=27℃
L
M
H
TEC1-12703
127
3
15.4
26.7
70
40
40
4.9
3.42
TEC1-12704
4
36.8
70
40
40
4.5
3.02
TEC1-12705
5
46.5
70
40
40
4.2
2.51
TEC1-12706
6
53.3
70
40
40
3.8
1.98
TEC1-12707
7
62.2
70
40
40
3.6
1.71
TEC1-12708
8
71.1
70
40
40
3.4
1.51
TEC1-12709
9
80.1
69
40
40
3.4
1.36
TEC1-12710
10
88.9
69
40
40
3.3
1.08
TEC1-12708
127
8
15.4
71.1
70
50
50
5.1
1.51
TEC1-12710
10
88.9
70
50
50
4.5
1.12
TEC1-12712
12
106.7
70
50
50
4.2
0.91
TEC1-12714
14
124.4
70
50
50
4.3
0.81
TEC1-12715
15
133.3
70
50
50
3.6
0.75
TEC1-12718
18
160.1
70
50
50
3.6
0.68
TEC1-12720
20
177.8
69
50
50
3.4
0.59
TEC1-12722
22
195.6
69
50
50
3.4
0.55
TEC1-12726
26
232.5
68
50
50
3.3
0.48
TEC1-12730
30
266.7
68
50
50
3.1
0.43
TEC1-12710
127
10
15.4
88.9
70
62
62
6.1
1.05
TEC1-12712
12
106.7
70
62
62
5.9
0.91
TEC1-12714
14
124.4
70
62
62
5.9
0.81
TEC1-12715
15
133.3
70
62
62
5.8
0.75
TEC1-12718
18
160.1
70
62
62
5.6
0.68
TEC1-12720
20
177.8
70
62
62
5.6
0.59
TEC1-12722
22
195.6
70
62
62
5.3
0.55
TEC1-12726
26
232.5
69
62
62
4.3
0.48
TEC1-12730
30
266.7
69
62
62
3.9
0.43
TEC1-12740
40
355.6
68
62
62
3.6
0.27

 

Notes:
  1.The operating temperature: 125, 150, 200.
  2.The length of lead wire could be fixed by clients, the common length is 150mm.
  3.The sealing of TE modules: Unsealing, Silicon, Epoxy, the normal sealing is silicon gel.