The Calculation of Qcmax (W) |
A.1 When the temperature of heat side at 27℃±1℃, △T=0,I=Imax
The formula (1)
Qcmax=0.07NI……………………………………………………(1)
N--couples; I--Imax (A)。
A.2 When the temperature of the heat side at 3~40℃, Qcmax (W) has to be adjusted as formula (2):
The formula (2)
Qcmax|Th= Qcmax[1+0.0042(Th-27)] …………………………(2)
Qcmax: Th27℃±1℃(W);
Qcmax|Th: the real testing Th=3~40℃.
|
| |
|