Performance Curves
   

The Calculation of Qcmax (W)

A.1 When the temperature of heat side at 27℃±1℃, △T=0,I=Imax

      The formula (1)
   Qcmax=0.07NI……………………………………………………(1)

   N--couples; I--Imax (A)。

A.2 When the temperature of the heat side at 3~40℃, Qcmax (W) has to be adjusted as formula (2):

      The formula (2) 
     Qcmax|Th= Qcmax[1+0.0042(Th-27)] …………………………(2)

      Qcmax: Th27℃±1℃(W);
      Qcmax|Th:  the real testing Th=3~40℃.

 
 